Chardon 35kV Bushing Insert | Field-replaceable ANSI/IEEE 200A loadbreak design. All-copper, IEEE 386-7B compliant. Shielded/submersible. Installs by hand/tool.

What Are You Looking For?
LB235B150 is 35KV 200A Intergral Loadbreak Bushing Insert, can used with Large Interface Elbow Connector. LB235B150GCX is the PN include gasket and Clamp.
Product Name :
Three-phase Integral Loadbreak BushingCatalog Number :
LB235B150 / LB235B150GCXRated Voltage :
35KVRated Current :
200ALead Time :
4 weeksChardon 35kV Bushing Insert | Field-replaceable ANSI/IEEE 200A loadbreak design. All-copper, IEEE 386-7B compliant. Shielded/submersible. Installs by hand/tool.
35KV 600A, Deadbreak bushing, 35 kV, Phase to ground: 21.1 kV, AC 1 min: 50 kV, DC 15 min: 103 kV, BIL: 150 kV, Corona: 26 kV, 600 A
DB925B125 is deadbreak bushing, 25KV 600A from Eaton Cooper Power system. DB925B125 is the Apparatus Deadbreak HV Bushing with Gasket and Clamp.
25KV 600A, Deadbreak Apparatus Bushing, with gasket and Clamp ,Epoxy,No stud, Cooper Power System, HV Bushing
25KV 600A, Deadbreak Apparatus Bushing, No gasket,,Epoxy,No stud, Cooper Power System, HV Bushing
Eaton Cooper Power series insulated standoff bushing, EPDM rubber, 15 kV, Phase to ground: 8.3 kV, AC 1 min: 34 kV, DC 15 min: 53 kV, BIL: 95 kV, Corona: 11 kV, 200 A, Individual box kit
35 kV, 200A Loadbreak Protective Cap, can replace Cooper LPC235, IEEE std
25KV 200A, Loadbreak Protective Cap, LPC225's alternative, suitable for LBI225
LB235B150 is 35KV 200A Intergral Loadbreak Bushing Insert, can used with Large Interface Elbow Connector. LB235B150GCX is the PN include gasket and Clamp.
Eaton Cooper Power™ Series 35kV three-phase loadbreak bushing delivers IEEE Std 386™ compliant separable insulated connector performance for underground distribution switching. Its patented one-piece design eliminates insert-to-well interface risks in bushing well systems, providing fully shielded submersible connections for oil-filled transformers, switchgear, and Envirotemp™ FR3™ fluid insulated equipment.
✔ Superior Arc Protection
Ablative arc interrupter + fault-activated piston contact assembly enables 36.6kV/10-cycle fault closing rating with industry-leading arc quenching
✔ Zero-Resistance Conductivity
Continuous copper/copper alloy current path minimizes energy loss
✔ Error-Proof Color Coding
▸ Voltage Rating: 21.1/36.6kV three-phase
▸ Applications: Underground distribution switching / Oil-immersed equipment
▸ Compliance: IEEE 386 standards; Compatible with mineral oil & FR3™ fluids
25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
80A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
25A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
65A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
50A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
40A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
25A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
15A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
12A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System