ANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.

What Are You Looking For?
LB235B150 is 35KV 200A Intergral Loadbreak Bushing Insert, can used with Large Interface Elbow Connector. LB235B150GCX is the PN include gasket and Clamp.
Product Name :
Three-phase Integral Loadbreak BushingCatalog Number :
LB235B150 / LB235B150GCXRated Voltage :
35KVRated Current :
200ALead Time :
4 weeksANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.
ANSI 15 kV to 34 kV transformer bushing series with 2-hole terminal pads, 125 A to 417 A ratings and multiple shed profiles.
ANSI 15 kV and 25 kV transformer bushing series for 125 A to 600 A with 2-hole, 4-hole and 6-hole terminal pad variants.
ANSI 15 kV to 34 kV, 55 A transformer bushings with 1-hole or 2-hole terminal pads and 4- to 17-shed profiles.
ANSI 15 kV to 34 kV, 55 A transformer bushing series with rod terminals in Ø8.7 mm and Ø13 mm versions and multiple shed profiles.
ANSI 10 kV transformer bushing series covering 800 A to 2000 A with 4-hole, 6-hole and 8-hole terminal pad options.
ANSI 5 kV transformer bushing series covering 630 A to 4000 A with 2-hole, 4-hole and 6-hole terminal pad configurations.
High-current ANSI 1.2 kV transformer bushing series for 1400 A to 3150 A, with 4-hole, 6-hole and high-hole-count terminal pad variants.
ANSI 1.2 kV transformer bushing series covering 417 A to 1200 A with pin, head-pin and multi-hole terminal pad options.
ANSI 1.2 kV transformer bushing series covering 125 A and 250 A ratings with pin, 1-hole, 2-hole and 4-hole terminal configurations.
LB235B150 is 35KV 200A Intergral Loadbreak Bushing Insert, can used with Large Interface Elbow Connector. LB235B150GCX is the PN include gasket and Clamp.
Eaton Cooper Power™ Series 35kV three-phase loadbreak bushing delivers IEEE Std 386™ compliant separable insulated connector performance for underground distribution switching. Its patented one-piece design eliminates insert-to-well interface risks in bushing well systems, providing fully shielded submersible connections for oil-filled transformers, switchgear, and Envirotemp™ FR3™ fluid insulated equipment.
✔ Superior Arc Protection
Ablative arc interrupter + fault-activated piston contact assembly enables 36.6kV/10-cycle fault closing rating with industry-leading arc quenching
✔ Zero-Resistance Conductivity
Continuous copper/copper alloy current path minimizes energy loss
✔ Error-Proof Color Coding
▸ Voltage Rating: 21.1/36.6kV three-phase
▸ Applications: Underground distribution switching / Oil-immersed equipment
▸ Compliance: IEEE 386 standards; Compatible with mineral oil & FR3™ fluids



ANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.
ANSI 15 kV to 34 kV transformer bushing series with 2-hole terminal pads, 125 A to 417 A ratings and multiple shed profiles.
ANSI 15 kV and 25 kV transformer bushing series for 125 A to 600 A with 2-hole, 4-hole and 6-hole terminal pad variants.
ANSI 15 kV to 34 kV, 55 A transformer bushings with 1-hole or 2-hole terminal pads and 4- to 17-shed profiles.
ANSI 15 kV to 34 kV, 55 A transformer bushing series with rod terminals in Ø8.7 mm and Ø13 mm versions and multiple shed profiles.
ANSI 10 kV transformer bushing series covering 800 A to 2000 A with 4-hole, 6-hole and 8-hole terminal pad options.
ANSI 5 kV transformer bushing series covering 630 A to 4000 A with 2-hole, 4-hole and 6-hole terminal pad configurations.
High-current ANSI 1.2 kV transformer bushing series for 1400 A to 3150 A, with 4-hole, 6-hole and high-hole-count terminal pad variants.
ANSI 1.2 kV transformer bushing series covering 417 A to 1200 A with pin, head-pin and multi-hole terminal pad options.
ANSI 1.2 kV transformer bushing series covering 125 A and 250 A ratings with pin, 1-hole, 2-hole and 4-hole terminal configurations.