ANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.

What Are You Looking For?
35KV 600A, Deadbreak bushing, 35 kV, Phase to ground: 21.1 kV, AC 1 min: 50 kV, DC 15 min: 103 kV, BIL: 150 kV, Corona: 26 kV, 600 A
Product Name :
Eaton Cooper Power series deadbreak bushingCatalog Number :
DB635B150Rated Voltage :
35KVRated Current :
600AType :
Deadbreak bushingLead Time :
Contact usANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.
ANSI 15 kV to 34 kV transformer bushing series with 2-hole terminal pads, 125 A to 417 A ratings and multiple shed profiles.
ANSI 15 kV and 25 kV transformer bushing series for 125 A to 600 A with 2-hole, 4-hole and 6-hole terminal pad variants.
ANSI 15 kV to 34 kV, 55 A transformer bushings with 1-hole or 2-hole terminal pads and 4- to 17-shed profiles.
ANSI 15 kV to 34 kV, 55 A transformer bushing series with rod terminals in Ø8.7 mm and Ø13 mm versions and multiple shed profiles.
ANSI 10 kV transformer bushing series covering 800 A to 2000 A with 4-hole, 6-hole and 8-hole terminal pad options.
ANSI 5 kV transformer bushing series covering 630 A to 4000 A with 2-hole, 4-hole and 6-hole terminal pad configurations.
High-current ANSI 1.2 kV transformer bushing series for 1400 A to 3150 A, with 4-hole, 6-hole and high-hole-count terminal pad variants.
ANSI 1.2 kV transformer bushing series covering 417 A to 1200 A with pin, head-pin and multi-hole terminal pad options.
ANSI 1.2 kV transformer bushing series covering 125 A and 250 A ratings with pin, 1-hole, 2-hole and 4-hole terminal configurations.
35KV 600A, Deadbreak bushing, 35 kV, Phase to ground: 21.1 kV, AC 1 min: 50 kV, DC 15 min: 103 kV, BIL: 150 kV, Corona: 26 kV, 600 A

Eaton Cooper Power™ Series 600A 35kV deadbreak bushings fully comply with IEEE Std 386™-2006 for separable insulated connectors. Universally compatible with all IEEE 386™-2006 standard 600A connectors, including BOL-T™, T-OP™ II, and third-party systems.
✔ Grounding Reliability
Integrated ground screen + clamp-to-sidewall grounding ensures <2Ω resistance (per IEEE 386)
✔ Fluid Compatibility
Certified for transformer oil, Envirotemp™ FR3™, and equivalent dielectric fluids
✔ Tool-Free Installation
Sidewall-mount design with external clamping system
(Ref: Installation Guide S800-35-2)
IEEE 386™-2006 Tests
▸ 50 kV AC 60Hz/1min withstand
▸ 26 kV partial discharge threshold
Eaton Premium Protocols
▸ 150 kV impulse withstand testing
▸ X-ray fluoroscopic inspection
▸ Batch dissection analysis
Cross-Industry Applications
• Oil-immersed transformers
• Underground distribution switches
• FR3™ fluid-filled substation gear

ANSI 15 kV to 34 kV transformer bushing series with 4-hole terminal pads and current ratings from 125 A to 600 A.
ANSI 15 kV to 34 kV transformer bushing series with 2-hole terminal pads, 125 A to 417 A ratings and multiple shed profiles.
ANSI 15 kV and 25 kV transformer bushing series for 125 A to 600 A with 2-hole, 4-hole and 6-hole terminal pad variants.
ANSI 15 kV to 34 kV, 55 A transformer bushings with 1-hole or 2-hole terminal pads and 4- to 17-shed profiles.
ANSI 15 kV to 34 kV, 55 A transformer bushing series with rod terminals in Ø8.7 mm and Ø13 mm versions and multiple shed profiles.
ANSI 10 kV transformer bushing series covering 800 A to 2000 A with 4-hole, 6-hole and 8-hole terminal pad options.
ANSI 5 kV transformer bushing series covering 630 A to 4000 A with 2-hole, 4-hole and 6-hole terminal pad configurations.
High-current ANSI 1.2 kV transformer bushing series for 1400 A to 3150 A, with 4-hole, 6-hole and high-hole-count terminal pad variants.
ANSI 1.2 kV transformer bushing series covering 417 A to 1200 A with pin, head-pin and multi-hole terminal pad options.
ANSI 1.2 kV transformer bushing series covering 125 A and 250 A ratings with pin, 1-hole, 2-hole and 4-hole terminal configurations.