<p>50A 8.3KV Current Limiting Backup Fuse, ELSP Fuse, Oil Fuse, Cooper Power System</p>
![](https://www.jiuyingtech.com/wp-content/uploads/2024/08/Jiuying-Logo.png)
What Are You Looking For?
The dual sensing fuse protects the low-voltage side of the transformer from faults or overloads in terms of current and temperature, and can prevent the transformer from heating up for a long time due to overload or ambient temperature.
Product Name :
Dual Sensing Bay-O-Net FuseBrand :
Cooper Power SystemVoltage :
Max 23KVStandard :
ANSI, IEEESuitable For :
4000361C99FV<p>50A 8.3KV Current Limiting Backup Fuse, ELSP Fuse, Oil Fuse, Cooper Power System</p>
<p>15.5KV 125A, current limiting backup fuse, Under oil, 2.1 inch diameter, Distribution C, 50 kA max interrupt current, 500A min in, Cooper Power System</p>
<p>Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 65A, </p>
<p>High ampere overload Bay-O-Net fuse link, 125A, 15.5 kV, Cooper Power System, Bayonet Fuse</p>
<p>Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 40A, 38 kV, 38 kV Fuse Max, Current Rating 40A</p>
<p>Curve 11, 34.5kV Oil Expulsion Fuse, Transformer Protection, ANSI</p>
<p>Protective links are available in a variety of fuse sizes and voltage ranges up to 34.5 kV line-to-line grounded Y. In most applications today, the protective link is used in series with a partial range or back-up current limiting fuse such as the Hi-Tech Trans-Guard™ family of current limiting fuses.</p> <p> </p>
<p>Oil-immersed current limiting fuse used to protect the transformer from internal faults (coil short circuit protection). The maximum breaking current of the backup protection fuse device is 50kA.</p>
The dual sensing fuse is a main accessory for overcurrent protection of oil-immersed padmount transformers in power distribution systems. It is used in conjunction with the backup fuse (i.e. ELSP) to form a "two-stage protection solution". The dual sensing fuse protects the low-voltage side of the transformer from faults or overloads in terms of current and temperature, and can prevent the transformer from heating up for a long time due to overload or ambient temperature. The dual sensing fuse is installed in a plug-in fuse barrel, which is easy to replace, simple to install and reliable in operation. Therefore, it is widely used for high-voltage side protection of American padmount transformers.
Current Rating(A) | Catalog Number |
3 | 4000358C03B |
8 | 4000358C05B |
15 | 4000358C08B |
25 | 4000358C10B |
50 | 4000358C12B |
65 | 4000358C14B |
100 | 4000358C16CB |
140 | 4000358C18CB |
<p>35 kV, 200A Loadbreak Protective Cap, can replace Cooper LPC235, IEEE std</p>
<p>25KV 200A, Loadbreak Protective Cap, LPC225's alternative, suitable for LBI225</p>
<p>15 kV, 200A Loadbreak Protective Cap, LPC215 replacement, suitable for LBI215 Load break Bushing Insert</p>
<p>50A 8.3KV Current Limiting Backup Fuse, ELSP Fuse, Oil Fuse, Cooper Power System</p>
<p>35KV 200A, Loadbreak Elbow Connector, IEEE Std, Transformer Parts, separable connectors</p>
<p>35KV 200A, Loadbreak Elbow Connector, Padmount Transformer Parts</p>
<p>25 kV, 200A Loadbreak Elbow, Transformer Parts, IEEE Std, LBI225 Equivalent</p>
<p>200 A, 15 kV Class Loadbreak Junction, IEEE Std, Transformer Parts, Loadbreak Seperable Cable Accessory</p>