25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System

What Are You Looking For?
The dual sensing fuse protects the low-voltage side of the transformer from faults or overloads in terms of current and temperature, and can prevent the transformer from heating up for a long time due to overload or ambient temperature.
Product Name :
Dual Sensing Bay-O-Net FuseBrand :
Cooper Power SystemVoltage :
Max 23KVStandard :
ANSI, IEEESuitable For :
4000361C99FV25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
80A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
25A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
65A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
50A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
40A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
25A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
15A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
12A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
The dual sensing fuse is a main accessory for overcurrent protection of oil-immersed padmount transformers in power distribution systems. It is used in conjunction with the backup fuse (i.e. ELSP) to form a "two-stage protection solution". The dual sensing fuse protects the low-voltage side of the transformer from faults or overloads in terms of current and temperature, and can prevent the transformer from heating up for a long time due to overload or ambient temperature. The dual sensing fuse is installed in a plug-in fuse barrel, which is easy to replace, simple to install and reliable in operation. Therefore, it is widely used for high-voltage side protection of American padmount transformers.
Current Rating(A) | Catalog Number |
3 | 4000358C03B |
8 | 4000358C05B |
15 | 4000358C08B |
25 | 4000358C10B |
50 | 4000358C12B |
65 | 4000358C14B |
100 | 4000358C16CB |
140 | 4000358C18CB |
300 LBS WOG Electrical Valve: C377 copper alloy body, Teflon disc & Viton seals. Industry-compliant, closed-position delivery, 12/box with “Made in China” labeling. Ideal for water, oil, and gas applications.
The pressure relief valve is mainly used to prevent the gas pressure in the container from exceeding a predetermined value. When the pressure is higher than the release pressure(Pressure release opening value: P=0.03 ± 0.01MPa Or P=0.06 ± 0.01MPa) the valve will automatically open to allow the gas to leak。 The material is copper
The vacuum pressure gauge is a pressure measuring instrument specially designed for box-type power transformers. The measuring range is -10~10PSIG.
The UHZK-03 Electric Contact Oil Level Gauge is designed for indicating the oil level in the tank of oil-immersed transformer,it is composed of float, connecting lever, holder, magnet steel and indicator, terminal box, relay etc. With the holder completely separating the indicator from the float, it is possible for the gauge to be sealed.
This type oil temperature gauge is a specialized instrument suitable for temperature measurement and control of various small transformers. This gauge has the characteristics of sensitive response, clear indication, convenient installation, and good reliability.
The transformer oil temperature gauge is suitable for the instrument installed on the side wall of the transformer for temperature measurement and indication. The temperature measurement range is 0~120°C.
This Transformer LV Bushing is epoxy molded, it is removable secondary bushing, and is used for connecting cables outside of pad-mounted transformer tanks to the secondary coil winding leads inside the tanks. It is designed for use in transformer oil or an approved equivalent.
25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System