The current sensing BON fuse is a main accessory of the overcurrent protection device of the oil-immersed padmount transformer in the power distribution system.
Product Name :
Current Sensing Bay-O-Net FuseBrand :
Cooper Power SystemVoltage :
Max 23KVStandard :
ANSISuitable For :
4000361C99FV<p>50A 8.3KV Current Limiting Backup Fuse, ELSP Fuse, Oil Fuse, Cooper Power System</p>
<p>15.5KV 125A, current limiting backup fuse, Under oil, 2.1 inch diameter, Distribution C, 50 kA max interrupt current, 500A min in, Cooper Power System</p>
<p>Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 65A, </p>
<p>High ampere overload Bay-O-Net fuse link, 125A, 15.5 kV, Cooper Power System, Bayonet Fuse</p>
<p>Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 40A, 38 kV, 38 kV Fuse Max, Current Rating 40A</p>
<p>Curve 11, 34.5kV Oil Expulsion Fuse, Transformer Protection, ANSI</p>
<p>Protective links are available in a variety of fuse sizes and voltage ranges up to 34.5 kV line-to-line grounded Y. In most applications today, the protective link is used in series with a partial range or back-up current limiting fuse such as the Hi-Tech Trans-Guard™ family of current limiting fuses.</p> <p> </p>
<p>Oil-immersed current limiting fuse used to protect the transformer from internal faults (coil short circuit protection). The maximum breaking current of the backup protection fuse device is 50kA.</p>
The current sensing BON fuse is a main accessory of the overcurrent protection device of the oil-immersed padmount transformer in the power distribution system. It is used t o isolate the fault current to protect the equipment, or to isolate the faulty equipment to protect the power system. It can be used for single-phase transformers, self-protected transformers or other distribution equipment not exceeding 500kVA, and can also be u sed for three-phase transformers not exceeding 1500kVA.
Overcurrent protection fuses are generally used in conjunction with backup fuses (ie ELSP) to form a "two-stage protection" scheme in which the current sensing fuse and the backup fuse are connected in series. The current sensing fuse performs overload pro tection and secondary side protection, and the backup protection fuse is used to dry protect the internal fault of the transformer (coil short circuit fault, etc.).
The current sensing fuse is installed in a plug-in fuse barrel, which is very convenien to replace, simple t o install and reliable in operation. Therefore, it is widely used for high-voltage side prot ection of ANSI Padmount transformers.
Current Rating(A) | Catalog Number |
6 | 4000353C04 |
10 | 4000353C06 |
15 | 4000353C08 |
25 | 4000353C10 |
40 | 4000353C12 |
65 | 4000353C14 |
100 | 4000353C16 |
140 | 4000353C17 |
<p>35 kV, 200A Loadbreak Protective Cap, can replace Cooper LPC235, IEEE std</p>
<p>25KV 200A, Loadbreak Protective Cap, LPC225's alternative, suitable for LBI225</p>
<p>15 kV, 200A Loadbreak Protective Cap, LPC215 replacement, suitable for LBI215 Load break Bushing Insert</p>
<p>50A 8.3KV Current Limiting Backup Fuse, ELSP Fuse, Oil Fuse, Cooper Power System</p>
<p>35KV 200A, Loadbreak Elbow Connector, IEEE Std, Transformer Parts, separable connectors</p>
<p>35KV 200A, Loadbreak Elbow Connector, Padmount Transformer Parts</p>
<p>25 kV, 200A Loadbreak Elbow, Transformer Parts, IEEE Std, LBI225 Equivalent</p>
<p>200 A, 15 kV Class Loadbreak Junction, IEEE Std, Transformer Parts, Loadbreak Seperable Cable Accessory</p>