Product Code: CHBON Chardon Bayonet Fuse Holders are used to protect transformers, switchgear, and distribution systems. They are designed for use in oil filled (or approved equivalents) single pha

What Are You Looking For?
Protective links are available in a variety of fuse sizes and voltage ranges up to 34.5 kV line-to-line grounded Y. In most applications today, the protective link is used in series with a partial range or back-up current limiting fuse such as the Hi-Tech Trans-Guard™ family of current limiting fuses.
Product Name :
Expulsion FuseBrand :
ABBVoltage :
15KV/23KV/34.5KVProduct Code: CHBON Chardon Bayonet Fuse Holders are used to protect transformers, switchgear, and distribution systems. They are designed for use in oil filled (or approved equivalents) single pha
Número de Pieza: CHIL The Chardon Isolation Link is used in series with bayonet type expulsion fuses to provide extra protection during re-fusing operations. Isolation links are not fuses and do no
Product Code: CHIL The Chardon Isolation Link is used in series with bayonet type expulsion fuses to provide extra protection during re-fusing operations. Isolation links are not fuses and do not h
Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 65A,
High ampere overload Bay-O-Net fuse link, 125A, 15.5 kV, Cooper Power System, Bayonet Fuse
Eaton Cooper Power series 38kV Bay-O-Net fuse link, Bay-O-Net, Dual sensing, 40A, 38 kV, 38 kV Fuse Max, Current Rating 40A
Curve 11, 34.5kV Oil Expulsion Fuse, Transformer Protection, ANSI
Oil-immersed current limiting fuse used to protect the transformer from internal faults (coil short circuit protection). The maximum breaking current of the backup protection fuse device is 50kA.
The Hitachi ABB Power Grids Distribution Transformer Components protective link is an oil-immersed, expulsion type fuse designed for use in the high voltage circuit of distribution equipment. Protective links are available in a variety of fuse sizes and voltage ranges up to 34.5 kV line-to-line grounded Y. In most applications today, the protective link is used in series with a partial range or back-up current limiting fuse such as the Hi-Tech Trans-Guard™ family of current limiting fuses.
The standard offering for the 15 kV protective link featured below includes a long lead. This product is also offered with a short lead or for block mounting. Please contact Hitachi ABB Power Grids Distribution Transformer Components for details.
| Current rating (Amperes) | Fuse curve | Package quantity | Part number through 15kV |
Part number through 23kV |
Part number through 34.5kV |
| 4.5 | 2 | 10 | 592B581G01 | 779C667G01 | 345B995G21 |
| 6.2 | 3 | 10 | 592B581G02 | 779C667G02 | 345B995G29 |
| 7 | 3A | 10 | 592B581G11 | 779C667G03 | 345B995G22 |
| 8.2 | 4 | 10 | 592B581G06 | 779C667G08 | 345B995G33 |
| 11 | 5 | 10 | 592B581G03 | 779C667G04 | 345B995G23 |
| 13 | 5A | 10 | 592B581G12 | 779C667G09 | 345B995G24 |
| 16 | 6 | 10 | 592B581G04 | 779C667G05 | 345B995G28 |
| 21 | 7 | 10 | 592B581G05 | 779C667G06 | 345B995G25 |
| 24 | 7A | 10 | 592B581G13 | 779C667G33 | 345B995G34 |
| 30 | 8 | 10 | 592B581G07 | 779C667G07 | 345B995G26 |
| 49 | 9 | 10 | 592B581G08 | 779C667G34 | 345B995G27 |
| 71 | 10 | 10 | 592B581G09 | 779C667G35 | 345B995G31 |
| 102 | 11 | 10 | 592B581G14 | 779C667G36 | 345B995G32 |
| 160 | 12 | 10 | 592B581G31 | Not available | Not available |
| 230 | 13 | 10 | 592B581G32 | Not available | Not available |
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.