Product Code: CKEL The Chardon Load Break Switch (LBS) allows for safe making and breaking of load currents within a powered system. With manual and remote operation capabilities, the LBS provides

What Are You Looking For?
4 Positition Load Break Switch, Three-phase, 630 A/300 A/200 A, 60 Hz, Bolt mount, V-Blade, Cast brass, hotstick operable, Make before break
Product Name :
Four-position bolt-in mount loadbreak switchCatalog Number :
LS4BH3V12MVoltage :
15.5 kV/27.8 kV/38 kVCurrent Rating :
630 A/300 A/200 AType :
V-BladeLeadtime :
4 weeksProduct Code: CKEL The Chardon Load Break Switch (LBS) allows for safe making and breaking of load currents within a powered system. With manual and remote operation capabilities, the LBS provides
Four-position bolt-in mount loadbreak switch, Single-phase, 630 A/300 A/200 A, 60 Hz, Bracket mount, V-Blade, Cast brass, hotstick operable, Make before break
Two-position bolt-in mount loadbreak switch, Three-phase, 27KV, 400 A, 60 Hz, Hotstick operable, w/ optional indicator plate
Two-position bolt mount loadbreak switch, Three-phase, 300 A, 60 Hz, Bolt mount, Hotstick operable, with optional indicator plate
Four-position bolt-in mount loadbreak switch, Three-phase, 600 A, 60 Hz, Bracket mount, T-Blade, Cast brass, hotstick operable, Break Before Make
Four-position bolt-in mount loadbreak switch, 3-phase, 630 A/300 A/200 A, 60 Hz, Bracket mount, T-Blade, Cast brass, hotstick operable, Make before break
Four-position bolt-in mount loadbreak switch, Single-phase, 630 A/300 A/200 A, 60 Hz, Bracket mount, T-Blade, Cast brass, hotstick operable, Make before break
Two-position ring mount loadbreak switch, 1-phase, 300 A, 60 Hz, Ring mount, Hotstick operable, Cooper Power System
Eaton Cooper Power series two-position ring mount loadbreak switch, Three-phase, 300 A, 60 Hz, Ring mount, Hotstick operable, w/ optional indicator plate, Standard, Individually boxed
Eaton Cooper Power series four-position bolt-in mount loadbreak switch, Three-phase, 630 A/300 A/200 A, 60 Hz, Bracket mount, V-Blade, Cast brass, hotstick operable, Make before break, Individually boxed


| Bolt-in Systm Load Break Switch | ||
| LS4BH1S12B | LS4BH3S12B | LS4BH2S16B |
| LS4BH1D12B | LS4BH3D12B | LS4BH2D16B |
| LS4BH1R12B | LS4BH3R12B | LS4BH2R16B |
| LS4BH1L12B | LS4BH3L12B | LS4BH2L16B |
| LS4BH1V12B | LS4BH3V12B | LS4BH2V16B |
| LS4BH1T12B | LS4BH3T12B | LS4BH2T16B |
| LS4BH1V12M | LS4BH3V12M | LS4BH2V16M |
| LS4BH1T12M | LS4BH3T12M | LS4BH2T16M |
| LS4BH2S12B | LS4BH1S16B | LS4BH3S16B |
| LS4BH2D12B | LS4BH1D16B | LS4BH3D16B |
| LS4BH2R12B | LS4BH1R16B | LS4BH3R16B |
| LS4BH2L12B | LS4BH1L16B | LS4BH3L16B |
| LS4BH2V12B | LS4BH1V16B | LS4BH3V16B |
| LS4BH2T12B | LS4BH1T16B | LS4BH3T16B |
| LS4BH2V12M | LS4BH1V16M | LS4BH3V16M |
| LS4BH2T12M | LS4BH1T16M | LS4BH3T16M |
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.