Product Code: CH200PLG The Chardon Bushing Well Insulated Plug is an accessory product to 15/25/28/35 kV 200A bushing well. It is designed to physically seal and electrically insulate the Loadbre

What Are You Looking For?
Eaton Cooper Power series insulated standoff bushing, EPDM rubber, 15 kV, Phase to ground: 8.3 kV, AC 1 min: 34 kV, DC 15 min: 53 kV, BIL: 95 kV, Corona: 11 kV, 200 A, Individual box kit
Product Name :
Insulated Standoff BushingCatalog Number :
ISB215Voltage :
15KVRated Current :
200AType :
Insulated Standoff BushingProduct Code: CH200PLG The Chardon Bushing Well Insulated Plug is an accessory product to 15/25/28/35 kV 200A bushing well. It is designed to physically seal and electrically insulate the Loadbre
Product Code: CH200BW The Chardon 200A 15kV,25kV,28kV and 35kV Class bushing well meets all requirements of IEEE standard 386-1995 (separable insulated connector system). It is designed for the te
Product Code: 42-BE1250 The Chardon 42kV 1250A Bushing Extender can be used for temporary or permanent applications and provides a submersible, fully shielded insulated connection between energized
Product Code: 36-DIB630 The Chardon 36 kV Interface C equipment bushing meets the full requirement of CENELEC EN 50180 and IEC 60137, provides a bolted interface made of quality epoxy. The part i
Product Code: 72-DIB630,72-DIB1250 The Chardon 72.5 kV Interface F equipment bushing meets the full requirement of CENELEC EN 50181 and IEC 60137, provides a bolted interface made of quality epoxy.
Product Code: 36-DIB400 The Chardon 36 kV Interface B equipment bushing provides a plug-in interface made of quality epoxy, meeting the full requirements of CENELEC EN 50180 and IEC 60137. The par
Product Code: 24-DBI250 The Chardon Deadbreak Bushing Insert threads into a standard 250A bushing well. It is a fully shielded, fully submersible separable connector designed for deadbreak operatio
Product Code: 24-DIB250 The Chardon 24kV Interface A equipment bushing meets the full requirement of EN 50180, EN 50181&IEC 60137, provides a sliding interface made of quality epoxy. Down
Product Code: 25-BE600, 35-BE900 The Chardon 25/35 kV 600/900A bushing Extender allows for coupling reducing tap plugs, connecting plugs and apparatus bushings. When assembled to mating apparatus,
Product Code: 25-SOB600 The Insulated Standoff bushings are designed to be installed in the parking stand bracket mounted on the transformer or other apparatus. A cable is connected to the system g
Eaton Cooper Power series insulated standoff bushing, EPDM rubber, 15 kV, Phase to ground: 8.3 kV, AC 1 min: 34 kV, DC 15 min: 53 kV, BIL: 95 kV, Corona: 11 kV, 200 A, Individual box kit
Eaton's Cooper Power series 200 A, 15 kV insulated standoff bushing meets the full requirements of IEEE Std 386-2006 standard - Separable Insulated Connector Systems, and provides a single loadbreak interface made of high quality peroxide cured EPDM rubber. It is used to isolate and sectionalize energized cable in pad-mounted cabinets, underground vaults, and other apparatus. Temporary or permanent parking of energized 200 A, 8.3/14.4 kV loadbreak elbow connectors that conform to IEEE Std 386-2006 standard is simplified with use of the insulated standoff bushing.



200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.