25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System

What Are You Looking For?
High overload Bay-O-Net fuses provide better heat dissipation when used at higher load currents. The lower operating temperature allows the Bay-O-Net fuse protection program to be expanded to protect larger capacity transformers.
Product Name :
High ampere overload Bay-O-Net fuseBrand :
Cooper Power SystemVoltage :
8.3/15.5/23KVStandard :
ANSI, IEEESuitable For :
4000361C99FV25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
80A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
25A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
65A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
50A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
40A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
25A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
15A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
12A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
Eaton's Cooper Power Series high overload fuses are used to protect power distribution equipment from damaging currents and to protect distribution systems from equipment failures. The fuses are installed in Eaton's Cooper Power Series Bay-O-Net silver-plated fuse assembly. High overload fuses provide better heat dissipation when used at higher load currents. The lower operating temperature allows the Bay-O-Net fuse protection program to be expanded to protect larger capacity transformers.
Current Rating | Continuous Current Rating at 25°C* |
Catalog Number |
65 | 135 | 4038361C03CB |
100 | 165 | 4038361C04CB |
125 | 185 | 4038361C05CB |
Shorting Bar (Solid link) |
200 | 4038361C10CB |
300 LBS WOG Electrical Valve: C377 copper alloy body, Teflon disc & Viton seals. Industry-compliant, closed-position delivery, 12/box with “Made in China” labeling. Ideal for water, oil, and gas applications.
The pressure relief valve is mainly used to prevent the gas pressure in the container from exceeding a predetermined value. When the pressure is higher than the release pressure(Pressure release opening value: P=0.03 ± 0.01MPa Or P=0.06 ± 0.01MPa) the valve will automatically open to allow the gas to leak。 The material is copper
The vacuum pressure gauge is a pressure measuring instrument specially designed for box-type power transformers. The measuring range is -10~10PSIG.
The UHZK-03 Electric Contact Oil Level Gauge is designed for indicating the oil level in the tank of oil-immersed transformer,it is composed of float, connecting lever, holder, magnet steel and indicator, terminal box, relay etc. With the holder completely separating the indicator from the float, it is possible for the gauge to be sealed.
This type oil temperature gauge is a specialized instrument suitable for temperature measurement and control of various small transformers. This gauge has the characteristics of sensitive response, clear indication, convenient installation, and good reliability.
The transformer oil temperature gauge is suitable for the instrument installed on the side wall of the transformer for temperature measurement and indication. The temperature measurement range is 0~120°C.
This Transformer LV Bushing is epoxy molded, it is removable secondary bushing, and is used for connecting cables outside of pad-mounted transformer tanks to the secondary coil winding leads inside the tanks. It is designed for use in transformer oil or an approved equivalent.
25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System