Product Code: 72.5-RDTA196-10 The Chardon T-body Surge Arrester, a fully screened and submersible arrester that serves as the rear connector for the 72.5 kV, 1250A Front T-body . It is designed to

What Are You Looking For?
VariSTAR surge arresters are available in normal-duty, heavy-duty, and riser pole classifications and provide superior overvoltage protection for any electric distribution system.
Product Name :
IEEE Distribution Sureger ArresterCatalog Number :
UNS/UHS/URSRated Voltage :
3-36KVStandard :
IEEEProduct Code: 72.5-RDTA196-10 The Chardon T-body Surge Arrester, a fully screened and submersible arrester that serves as the rear connector for the 72.5 kV, 1250A Front T-body . It is designed to
Product Code: 51-RDTA134 The Chardon T-Body Surge Arrester is an arrester combined within a coupling(rear) T-Body interface. It is designed to protect apparatus, including transformers, switchgear,
Product Code: 36-RDTA102-10-42 The Chardon T-Body Surge Arrester is an arrester combined within a coupling (rear) T-Body interface. It is designed to protect apparatus, including transformers,
Product Code: 36-RDTA102-10 The Chardon T-Body Surge Arrester is an arrester combined within a coupling (rear) T-Body interface. It is designed to protect apparatus, including transformers, swi
Product Code: 34-RDTA85 34-RDTA95-10 The Chardon T-Body Surge Arrester is an arrester combined within a coupling (rear) T-Body interface. It is designed to protect apparatus, including transformer
Product Code: 26-RDTA66 26-RDTA72-10 The Chardon T-Body Surge Arrester is an arrester combined within a coupling (rear) T-Body interface. It is designed to protect appa
Product Code: 17-RDTA50/17-RDTA45 The Chardon T-Body Surge Arrester is an arrester combined within a coupling(rear) T-Body interface. It is designed to protect apparatus, including transformers, sw
Product Code: GLE200 The Chardon 15 kV, 25 kV & 35 kV Grounding Elbow provide a circuit between energized and non-energized sections of the distribution line. The grounding elbow can be assemb
Product Code: 15-LEA / 25-LEA / 35-LEA The Chardon Elbow Arrester is designed to provide overvoltage system protection by combining a metal oxide varistor module within a rubber elbow. Meeting the
Eaton's Cooper Power series molded polymer-housed heavy-duty distribution class surge arresters for systems up to 36kV meet or exceed the requirements of IEEE C62.11.
Eaton’s Cooper Power series VariSTAR distribution-class surge arresters are part of the UltraSIL polymer-housed surge arrester product line; normal-duty (5 kA), heavy-duty, and riser pole (10 kA) for MV systems to 36 kV
VariSTAR surge arresters are available in normal-duty, heavy-duty, and riser pole classifications and provide superior overvoltage protection for any electric distribution system.








| Arrester rating | With isolator and insulated hanger(Figure 3) | With isolator,insulated hanger and NEMA cross-arm bracket (Figure 4) | With insulated hanger without isolator(Figure 6) | With isolator,insulated hanger, and bracket(Figure 5) | ||
| 3 | UNS03030A1A1A1A | UNS03030A1A1B1A | UNS03030A0A1A1A | UNS03030A1C1C1C | ||
| 6 | UNS06040A1A1A1A | UNS06040A1A1B1A | UNS06040A0A1A1A | UNS06040A1C1C1C | ||
| 9 | UNS09050A1A1A1A | UNS09050A1A1B1A | UNS09050A0A1A1A | UNS09050A1C1C1C | ||
| 10 | UNS10050A1A1A1A | UNS10050A1A1B1A | UNS10050A0A1A1A | UNS10050A1C1C1C | ||
| 12 | UNS12060A1A1A1A | UNS12060A1A1B1A | UNS12060A0A1A1A | UNS12060A1C1C1C | ||
| 15 | UNS15070A1A1A1A | UNS15070A1A1B1A | UNS15070A0A1A1A | UNS15070A1C1C1C | ||
| 18 | UNS18080A1A1A1A | UNS18080A1A1B1A | UNS18080A0A1A1A | UNS18080A1C1C1C | ||
| 21 | UNS21090A1A1A1A | UNS21090A1A1B1A | UNS21090A0A1A1A | UNS21090A1C1C1C | ||
| 24 | UNS24100A1A1A1A | UNS24100A1A1B1A | UNS24100A0A1A1A | UNS24100A1C1C1C | ||
| 27 | UNS27110A1A1A1A | UNS27110A1A1B1A | UNS27110A0A1A1A | UNS27110A1C1C1A | ||
| 30 | UNS30120A1A1A1A | UNS30120A1A1B1A | UNS30120A0A1A1A | UNS30120A1C1C1A | ||
| 33 | UNS33130A1A1A1A | UNS33130A1A1B1A | UNS33130A0A1A1A | UNS33130A1C1C1A | ||
| 36 | UNS36140A1A1A1A | UNS36140A1A1B1A | UNS36140A0A1A1A | UNS36140A1C1C1A | ||
| Arrester rating | With isolator and insulated hanger(Figure 3) | With isolator,insulated hanger and NEMA cross-arm bracket (Figure 4) | With insulated hanger without isolator(Figure 6) | With isolator,insulated hanger, and bracket(Figure 5) | ||
| 3 | UHS03030A1A1A1A | UHS03030A1A1B1A | UHS03030A0A1A1A | UHS03030A1C1C1C | ||
| 6 | UHS06040A1A1A1A | UHS06040A1A1B1A | UHS06040A0A1A1A | UHS06040A1C1C1C | ||
| 9 | UHS09050A1A1A1A | UHS09050A1A1B1A | UHS09050A0A1A1A | UHS09050A1C1C1C | ||
| 10 | UHS10050A1A1A1A | UHS10050A1A1B1A | UHS10050A0A1A1A | UHS10050A1C1C1C | ||
| 12 | UHS12060A1A1A1A | UHS12060A1A1B1A | UHS12060A0A1A1A | UHS12060A1C1C1C | ||
| 15 | UHS15070A1A1A1A | UHS15070A1A1B1A | UHS15070A0A1A1A | UHS15070A1C1C1C | ||
| 18 | UHS18080A1A1A1A | UHS18080A1A1B1A | UHS18080A0A1A1A | UHS18080A1C1C1C | ||
| 21 | UHS21090A1A1A1A | UHS21090A1A1B1A | UHS21090A0A1A1A | UHS21090A1C1C1C | ||
| 24 | UHS24100A1A1A1A | UHS24100A1A1B1A | UHS24100A0A1A1A | UHS24100A1C1C1C | ||
| 27 | UHS27110A1A1A1A | UHS27110A1A1B1A | UHS27110A0A1A1A | UHS27110A1C1C1A | ||
| 30 | UHS30120A1A1A1A | UHS30120A1A1B1A | UHS30120A0A1A1A | UHS30120A1C1C1A | ||
| 33 | UHS33130A1A1A1A | UHS33130A1A1B1A | UHS33130A0A1A1A | UHS33130A1C1C1A | ||
| 36 | UHS36140A1A1A1A | UHS36140A1A1B1A | UHS36140A0A1A1A | UHS36140A1C1C1A | ||
| Arrester rating | With isolator and insulated hanger(Figure 3) | With isolator,insulated hanger and NEMA cross-arm bracket (Figure 4) | With insulated hanger without isolator(Figure 6) | With isolator,insulated hanger, and bracket(Figure 5) | ||
| 3 | URS03030A1A1A1A | URS03030A1A1B1A | URS03030A0A1A1A | URS03030A1C1C1C | ||
| 6 | URS06040A1A1A1A | URS06040A1A1B1A | URS06040A0A1A1A | URS06040A1C1C1C | ||
| 9 | URS09050A1A1A1A | URS09050A1A1B1A | URS09050A0A1A1A | URS09050A1C1C1C | ||
| 10 | URS10050A1A1A1A | URS10050A1A1B1A | URS10050A0A1A1A | URS10050A1C1C1C | ||
| 12 | URS12060A1A1A1A | URS12060A1A1B1A | URS12060A0A1A1A | URS12060A1C1C1C | ||
| 15 | URS15070A1A1A1A | URS15070A1A1B1A | URS15070A0A1A1A | URS15070A1C1C1C | ||
| 18 | URS18080A1A1A1A | URS18080A1A1B1A | URS18080A0A1A1A | URS18080A1C1C1C | ||
| 21 | URS21090A1A1A1A | URS21090A1A1B1A | URS21090A0A1A1A | URS21090A1C1C1C | ||
| 24 | URS24100A1A1A1A | URS24100A1A1B1A | URS24100A0A1A1A | URS24100A1C1C1C | ||
| 27 | URS27110A1A1A1A | URS27110A1A1B1A | URS27110A0A1A1A | URS27110A1C1C1A | ||
| 30 | URS30120A1A1A1A | URS30120A1A1B1A | URS30120A0A1A1A | URS30120A1C1C1A | ||
| 33 | URS33130A1A1A1A | URS33130A1A1B1A | URS33130A0A1A1A | URS33130A1C1C1A | ||
| 36 | URS36140A1A1A1A | URS36140A1A1B1A | URS36140A0A1A1A | URS36140A1C1C1A | ||
200A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
165A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
140A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
125A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 38.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
100A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
80A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.
65A 23.0kV, ABB Backup Current Limiting Fuse (Trans-Guard OS Shorty type), ANSI/IEEE C37.40 partial-range backup fuse for oil-immersed distribution transformers.