Chardon 35kV Bushing Insert | Field-replaceable ANSI/IEEE 200A loadbreak design. All-copper, IEEE 386-7B compliant. Shielded/submersible. Installs by hand/tool.

What Are You Looking For?
15 kV, 200A Loadbreak Protective Cap, LPC215 replacement, suitable for LBI215 Load break Bushing Insert
Product Name :
Loadbreak Protective CapCatalog Number :
15-LIC200Voltage :
15KVCurrent Rating :
200AType :
Loadbreak Protective CapLead Time :
4 weeksChardon 35kV Bushing Insert | Field-replaceable ANSI/IEEE 200A loadbreak design. All-copper, IEEE 386-7B compliant. Shielded/submersible. Installs by hand/tool.
35KV 600A, Deadbreak bushing, 35 kV, Phase to ground: 21.1 kV, AC 1 min: 50 kV, DC 15 min: 103 kV, BIL: 150 kV, Corona: 26 kV, 600 A
LB235B150 is 35KV 200A Intergral Loadbreak Bushing Insert, can used with Large Interface Elbow Connector. LB235B150GCX is the PN include gasket and Clamp.
DB925B125 is deadbreak bushing, 25KV 600A from Eaton Cooper Power system. DB925B125 is the Apparatus Deadbreak HV Bushing with Gasket and Clamp.
25KV 600A, Deadbreak Apparatus Bushing, with gasket and Clamp ,Epoxy,No stud, Cooper Power System, HV Bushing
25KV 600A, Deadbreak Apparatus Bushing, No gasket,,Epoxy,No stud, Cooper Power System, HV Bushing
Eaton Cooper Power series insulated standoff bushing, EPDM rubber, 15 kV, Phase to ground: 8.3 kV, AC 1 min: 34 kV, DC 15 min: 53 kV, BIL: 95 kV, Corona: 11 kV, 200 A, Individual box kit
35 kV, 200A Loadbreak Protective Cap, can replace Cooper LPC235, IEEE std
25KV 200A, Loadbreak Protective Cap, LPC225's alternative, suitable for LBI225
200 A, 15 kV Class Loadbreak Junction, IEEE Std, Transformer Parts, Loadbreak Seperable Cable Accessory
The Chardon Protective Cap is an accessory product to other 15 kV, 200A products with loadbreak interfaces (bushing inserts, loadbreak junctions, feed thru inserts, etc.). It is designed to physically seal and electrically insulate loadbreak bushing interfaces. When installed on a loadbreak bushing interface, and properly grounded using the attached drain wire, the Loadbreak Protective Cap provides a submersible, fully shielded insulated cap for energized bushings.
The Loadbreak Protective Cap can be used for temporary or permanent applications.
25A 23KV, Bay-O-Net, dual sensing, bayonet fuse, Pad Mount Transformer, Cooper Power System
120A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
80A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
25A 38kV Bayonet fuse link, Bay-O-Net, Dual sensing, Eaton Cooper Power System
65A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
50A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
40A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
25A 23KV, Bay-O-Net, dual element, bayonet fuse, Cooper Power System
15A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System
12A 23KV, Bay-O-Net, dual element, bayonet fuse,Cooper Power System